EXPLORE THE FEATURES
Product
Great variety of mullions (from 16 to 230 mm) and transoms (from 22.5 to 205.5) that solve the different aesthetic and constructive needs of any architectonic projects.
» Internal seen section: 52 mm.
» Extensive profile range, their mechanical unions allows for all types of façades to be built (vertically, inclined, 90° corners, corners, polygonal) as well as solving large and heavy glazing modulations.
» Water tightness elements: drainage pipettes, tear strip gaskets and vulcanized angles.
» In order to fix the glass to the supporting profiles, a pressed profile is needed, this profile is screwed to the mullions and transoms, and covered with an embellisher profile (cover profile).
» Excellent thermal and acoustic properties.
Technical Data
» Glazing
Maximum glazing 64 mm / Mínimum glazing 4 mm
*Consult us for greater thicknesses
» Opening possibilities
Hidden turn&tilt / Hidden side hung / Hidden top hung projecting
» Sections
Mullion 52 mm / Transom 52 mm
» Profile thickness
Mullion 2.1 and 3 mm / Transom 2.1 mm
» Polyamide strip length
6, 12 & 30 mm stackable profiles
» Minimum / Maximum opening dimensions
Hidden Top hung
Min. Width (L) = 500 mm / Min. Height (H) = 650 mm
Max. Width (L) = 2500 mm / Max. Height (H) = 2500 mm
Hidden Parallel Projecting
Min. Width (L) = 530 mm / Min. Height (H) = 530 mm
Max. Width (L) = 2000 mm / Min. Height (H) = 3000 mm
Hidden Side Hung / Turn&Tilt
Min. Width (L) = 500 mm / Min. Height (H) = 600 mm
Max. Width (L) = 1400 mm / Min. Height (H) = 1900 mm
» Maximum weight / sash
Hidden Top hung 180 kg / Hidden Parallel Projecting 200 kg / Hidden Side Hung / Turn&Tilt 100 kg
» Maximum weight of fixed lights
750 kg
Consult maximum weight and dimensions according to typologies
» Covers
85 mm deep elliptical cover / H shape cover, 34 mm deep / Rectangular cover: 14, 19 100 & 145 mm deep / Pyramid shape cover, 155 mm deep
» Finishes
Powder coating / Anodised
Test Center
» Transmittance
Ucw from 0.6 (W/m²K)
Please consult dimensions and glazing
» Certification CWCT British Standard
» Air permeability
(EN 12152) CLASS AE
» Water tightness
(EN 13114) CLASS RE1500
» Wind resistance
(EN 13116) APT
(Design loading 2000 Pa - security loading 3000 Pa). Test reference 3.00 x 3.50 m.